R-404A refrigerant from Ice Cold refills low- and medium-temperature refrigeration systems, including walk-in freezers and display cases, restoring reliable cooling with virgin refrigerant.
Notify Me When Available
Press & drag to view
R-404A refrigerant from Ice Cold is a proven solution for commercial and residential refrigeration systems that operate at low and medium temperatures. It is commonly used to refill existing refrigeration equipment that has lost refrigerant due to leaks, service work, or component replacement. Ice Cold R-404A is manufactured in the United States using 100% virgin refrigerant that has never been reclaimed or recycled, ensuring consistent composition and dependable system performance.
Ice Cold R-404A is used when recharging systems such as walk-in freezers, reach-in coolers, display cases, and other cold storage applications engineered for R-404A operation. Maintaining proper refrigerant levels is critical for preserving cooling performance, temperature stability, and compressor health. This refrigerant is intended for servicing existing refrigeration equipment and should not be used as a substitute for other refrigerant types.
Key Features
- 100% virgin R-404A refrigerant, never reclaimed or recycled
- Made in the USA for consistent quality and reliability
- Same-day shipping on orders placed by 3 PM EST, with free, fast, tracked delivery to any valid, verifiable U.S. address
Restore cold storage performance fast with a reliable commercial refrigeration refrigerant you can trust.
Available R-404A Cylinder Sizes
Ice Cold sells 100% virgin R-404A in 2.5, 5, 7.5, 11, and 24 lb cylinders. These sizes are aimed at commercial refrigeration and walk-in work. Select a size above to see price and availability. For pallet quantities, use the bulk-orders page.
You can also shop all R-404A refrigerant cylinders.
Notice
R-404A is intended for use only in systems designed for R-404A refrigerant. Installation, handling, and system charging must be performed by a licensed HVAC professional in accordance with EPA regulations.
Ratings & Reviews
R-404A Refrigerant FAQs
Who can buy R-404A refrigerant?
Only EPA Section 608 certified technicians, or businesses that employ at least one certified technician, can legally purchase R-404A for stationary air-conditioning and refrigeration equipment. See our EPA guidelines page for the full purchasing rules.
What R-404A cylinder sizes do you sell?
Ice Cold sells 100% virgin R-404A in 2.5, 5, 7.5, 11, and 24 lb cylinders. Pallet quantities are available on the bulk-orders page.
Where can I buy R-404A online?
Certified technicians can buy 100% virgin R-404A from Ice Cold for commercial refrigeration systems, including walk-in freezers and display cases. We offer free shipping and fast delivery. Orders placed by 3 PM EST ship the same business day. Once your order ships, tracking information is provided. Refrigerant is a hazardous material and is shipped in compliance with regulations. Choose a cylinder size on this page to order. Pallet quantities can be requested on the bulk-orders page.
What is R-404A refrigerant?
R-404A refrigerant is a commonly used commercial refrigeration refrigerant designed for low- and medium-temperature cooling.
It’s most often found in systems like walk-in freezers, display cases, and transport refrigeration. R-404A is known for its ability to maintain consistent, low temperatures—making it a go-to choice for businesses that rely on dependable cooling.
Why is R-404A refrigerant so widely used?
R-404A became popular because it delivers reliable, consistent cooling, especially in demanding low-temperature environments.
For years, it’s been a standard in commercial HVAC and refrigeration systems because it performs well under heavy use and keeps products at stable temperatures. That reliability is why many existing systems still depend on it today.
Is R-404A being phased out?
R-404A is not banned, but it is being phased down due to its high global warming potential (GWP).
Regulations are pushing the industry toward newer, lower-impact refrigerants. While R-404A is still available for servicing existing systems, many businesses are starting to plan for alternatives as part of long-term equipment strategy. See whether a retrofit or keeping R-404A makes sense in our R-404A refrigerant replacement guide.
Are there alternatives to R-404A refrigerant?
Yes—there are several lower-GWP alternatives to R-404A, including R-448A, R-449A, and R-407F.
These newer refrigeration refrigerants are designed to reduce environmental impact while still delivering strong cooling performance. The right option depends on your system and application, so it’s best to consult with a qualified technician before making a switch. Compare R-448A, R-449A, and when to keep R-404A in our R-404A refrigerant replacement guide.
Can I retrofit my system to replace R-404A?
In many cases, yes—but it depends on your equipment.
Some systems can be retrofitted to use a different refrigerant, but it’s not always a simple swap. Oil compatibility, pressure differences, and system components all need to be evaluated. A licensed HVAC professional can help determine if a retrofit is practical or if replacement makes more sense. Read the retrofit steps and how they differ from a drop-in in our R-404A refrigerant replacement guide.
What are the cost considerations when switching from R-404A?
Costs can vary depending on your system and the refrigerant you choose.
A retrofit may involve labor, new components, and refrigerant costs. While some alternatives may have a higher upfront cost, they can offer better efficiency and lower long-term operating expenses.
For many businesses, the decision comes down to balancing short-term costs with long-term savings and regulatory compliance.